Code 11 Enter/Exit Programming Mode
Product Reference Guide
163
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 11
symbology.
Variable Length —
For variable length decoding, a minimum and maximum length may be set.
Fixed Length —
For fixed length decoding, two different lengths may be set.
DEFAULT
Code 11 Length Control = Variable Length
Code 11 Length Control = Fixed Length
Code 11 Set Length 1
This feature specifies one of the bar code lengths for Code 11 Length Control. Length 1 is the
minimum label length if in
Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters. See
"Set Length 1" on page 239 for more
detailed programming instructions.
Select Code 11 Set Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar
cod
e above, then the bar code at left followed by dig-
its from the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code
to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
04 = Length 1 is 4 Characters
$CC1LC00
$CC1LC01
$CC1L1
~