Interleaved 2 of 5 (I 2 of 5) Enter/Exit Programming Mode
Product Reference Guide   
          137
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 1 is the 
minimum label length if in 
Variable Length Mode, or the first fixed length if in Fixed Length 
Mode. The length includes the bar code’s check and data characters.
The length can be set from 2 to 50 charac
ters in increments of two. See "Set Length 1" on 
page 239 for more detailed programming instructions.
Select I 2 of 5 Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar 
cod
e above, then the bar code at left followed by dig-
its from the Alphanumeric characters in 
Appendix D, 
Keypad
 representing your desired character(s). End 
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code 
to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
DEFAULT
06 = Length 1 is 6 Characters
$CI2L1
~