Specifies the amount of time the scanner looks for keyboard activity before it breaks the
keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms
increments.
NOTE
This feature applies ONLY to the Keyboard Wedge interface.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with
le
ading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to
page 39
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Prog.
Mode.
4. Scan the bar code: SELECT WEDGE QUIET
INTERVAL SETTING.
5. Scan the appropriate two digits from
the keypad in
Appendix D, Keypad
, that represent the
duration which was determined in the steps above. You w
ill hear a two-beep indication
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code to
abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure to set the Wed
ge Quiet Interval. See the table below for
examples of how to set this feature.
Table 13. Wedge Quiet Interval Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
10ms 150ms 600ms 850ms
2
Divide by 10 (and pad with
leading zeroes)
01 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT WEDGE QUIET INTERVAL SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE