BC412 Enter/Exit Programming Mode
Product Reference Guide
207
BC412 Length Control
This feature specifies either variable length decoding or fixed length decoding for the BC412
symbology.
Variable Length —
For variable length decoding, a minimum and maximum length may be set.
Fixed Length —
For fixed length decoding, two different lengths may be set.
DEFAULT
BC412 Length Control = Variable Length
BC412 Length Control = Fixed Length
BC412 Set Length 1
This feature specifies one of the bar code lengths for BC412 Length Control. Length 1 is the
minimum label length if in
Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s data characters only.
The length can be set from 0 to 50 characters. See
"Set Length 1" on page 239 for more
detailed programming instructions.
Select BC412 Set Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar
cod
e above, then the bar code at left followed by dig-
its from the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code
to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character
$CBCLC00
$CBCLC01
$CBCL1
~