Enter/Exit Programming Mode Plessey
212
Cobalto™ CO5300 Scanner
Plessey Set Length 1
This feature specifies one of the bar code lengths for Plessey Length Control. Length 1 is the
minimum label length if in
Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50
characters.
Table 4 provides some examples for setting Length 1. See "Set Length 1" on page 239 for
detailed instructions on setting this feature.
Table 4. Plessey Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Character 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT Plessey LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to
abort and not save the entry string. You can then
start again at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character