Enter/Exit Programming Mode Codabar
154
Cobalto™ CO5300 Scanner
Codabar Set Length 1
This feature specifies one of the bar code lengths for Codabar Length Control. Length 1 is
the minimum label length if in
Variable Length Mode, or the first fixed length if in Fixed
Length
Mode. Length includes the bar code’s start, stop, check and data characters. The
length must include at least one data character.
The length can be set from 3 to 50 characters. See
"Set Length 1" on page 239 for more
detailed programming instructions.
Select Codabar Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar
cod
e above, then the bar code at left followed by dig-
its from the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code
to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
$CCBL1
~