Enter/Exit Programming Mode Handshaking Control
22
Cobalto™ CO5300 Scanner
Handshaking Control
The data interface consists of an RS-232 port designed to operate either with or without the
hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking
Control includes the following options:
RTS — RTS is asserted during t
ransmissions. CTS is ignored.
RTS/CTS — RTS is asserted during tran
smissions. CTS gates transmissions.
RTS/XON/XOFF — RTS is asserted during t
ransmissions. CTS is ignored. XON and XOFF
gate transmissions.
RTS On/CTS — RTS is always ass
erted. CTS gates transmissions.
RTS/CTS Scan Control — RTS is asserted during transmissions.
CTS gates transmissions
and controls enable and disable state of scanner.
DEFAULT
Handshaking Control = RTS
Handshaking Control = RTS/CTS
Handshaking Control = RTS/XON/XOFF
Handshaking Control = RTS On/CTS
Handshaking Control = RTS/CTS Scan Control
$CR2HC00
$CR2HC01
$CR2HC02
$CR2HC03
$CR2HC04