Code 4 and Code 5 Common Configuration Items Enter/Exit Programming Mode
Product Reference Guide
203
Code 4 and Code 5 Minimum Reads
This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label
must be decoded before it is accepted as good read.
DEFAULT
Code 4 or Code 5 Minimum Reads = 1
Code 4 or Code 5 Minimum Reads = 2
Code 4 or Code 5 Minimum Reads = 3
Code 4 or Code 5 Minimum Reads = 4
$CC5MR01
$CC5MR02
$CC5MR03
$CC5MR04