Standard Factory Settings Enter/Exit Programming Mode
Product Reference Guide
23
RS-232/USB-COM Interfaces
The programming bar codes in this chapter allow modifications to the standard RS-232 and
USB-Com interfaces.
Standard Factory Settings
Reference Appendix B, Standard Defaults for a listing of standard factory settings.
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the
beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in
10ms increments. A setting of zero specifies no delay. See
"Label ID: Pre-loaded Sets" on
page 232
for more detailed programming instructions.
Intercharacter Delay = No Delay
Select Intercharacter Delay Setting
To configure this feature, scan the ENTER/EXIT bar
code
above, then the bar code at left followed by dig-
its from the Alphanumeric c
haracters in Appendix D,
Keypad
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
an
d not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
00 = No Intercharacter Delay
$CR2IC00
$CR2IC
~