EasyManuals Logo

Datalogic Cobalto C05300 User Manual

Datalogic Cobalto C05300
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
ACK NAK Options Enter/Exit Programming Mode
Product Reference Guide
27
ACK NAK Timeout Value
This option specifies the amount of time the scanner waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15
seconds) in 200ms increments. A selection of 0 disables the timeout. See
"ACK NAK Timeout
Value" on page 222
for more detailed programming instructions.
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT bar
cod
e above, then the bar code at left followed by dig-
its from the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code
to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
01 ACK NAK Timeout value is 200ms
$CR2AT
~

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Cobalto C05300 and is the answer not in the manual?

Datalogic Cobalto C05300 Specifications

General IconGeneral
BrandDatalogic
ModelCobalto C05300
CategoryBarcode Reader
LanguageEnglish

Related product manuals