Page #242 background imageLoading...
Page #242 background image
References
230
Cobalto™ CO5300 Scanner
Figure 4. Prefix and Suffix Positions
Prex SuxAIM IDLabel ID Label IDBar Code Data
00 - 20 Characters (ASCII)
AND
OR
OR...
Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies.
1. Determine which ASCII character(s) are to be ad
ded to scanned bar code data. In this
example, we’ll add a dollar sign (‘$’) as a prefix.
2. Go to
page 46
and scan the ENTER/EXIT PROGRAMMING MODE bar code, then scan the
SET GLOBAL PREFIX bar code.
3. Reference the
ASCII Chart
on the inside back cover of this manual to find the hex value
assigned to the desired character. The corresponding hex number for the ‘$’ charac
ter is
24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from
Appendix D, Keypad
.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code to
abort and not save the entry string. You can then start again at the begin-
ning.
4. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT bar
code to terminate the string.
5. Scan the ENTER/EXIT bar code once again
to exit Programming Mode.
6. The resulting message string would appear as follows:
Scanned bar code data: 12345
Resulting message string output: $12345

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Cobalto C05300 and is the answer not in the manual?

Datalogic Cobalto C05300 Specifications

General IconGeneral
BrandDatalogic
ModelCobalto C05300
CategoryBarcode Reader
LanguageEnglish

Related product manuals