2. Enter the appropriate information in the form as described below:
Field of View
Start Angle
Enter the field of view (FOV) start angle in the field provided. This will adjust the start
FOV angle to that specified.
In the example below, the original Start Angle of 30° is reduced to 25° degrees when
that value is entered.
Figure 43: Start/Stop Angle
NOTE: This option is only available for the DS8110 scanner.
Enter the field of view (FOV) stop angle in the field provided. This will adjust the start
FOV angle to that specified.
NOTE: This option is only available for the DS8110 scanner.
Select the check box to enable Advanced Code Reconstruction (ACR™) when
reading the code. If not checked, standard linear reading mode will be used.
Select the check box to improve code reconstruction when two or more codes (of
the same or different symbologies) are stacked one on top of the other with little or
no space between them.
Configure ETH-2
for Dedicated
Setup/Aux
In a master/slave system (scanner as master, not an SC5000), this option is
available for slave scanners. Select the check box to enable.
This option applies to the last slave scanner in the daisy-chain system, allowing the
open Ethernet port to work as a dedicated setup port.
In practice, you can always communicate using this port, but selecting the check
box turns off all of the other EBC traffic on that port.
CAUTION: This option must only be applied to the last slave scanner in
the EBC network. Applying this option to the other slaves will disrupt the
EBC network.