3.4 GENERAL ELECTRICAL INSTALLATION GUIDELINES AND
PRECAUTIONS
It is important that you follow these general precautions when installing, setting up, operating,
maintaining, troubleshooting or replacing any Datalogic products, parts or related equipment.
As you plan and install your scanner(s), be sure to keep the following guidelines in mind:
Determine the scanner is in the proper location as outlined in Chapter 2.
Leave adequate clearances (approximately 300mm [12 inches]) for wiring.
Route wires carefully to reduce or minimize electrical noise.
IMPORTANT: When planning your installation wiring, remember all power
connections must be quick-disconnect. For PERMANENTLY CONNECTED
EQUIPMENT a readily accessible disconnect device must be incorporated in
the building installation wiring. For PLUGGABLE EQUIPMENT the socket-
outlet must be installed near the equipment and must be easily accessible
WARNING: To assure no ESD damage will occur, be sure to observe the
precautions outlined in the Introduction to this manual.
IMPORTANT: Ground the mounting structure to safety ground (protective
earth ground (PE)). See wiring recommendations for safety ground.