TROUBLESHOOTING
255
7
7.2 ERROR CODES AND RESOLUTIONS
Error
Code
Description
Severity
Explanation
Symptom
Troubleshooting
Action required
1
Node not
responding
Error
In a Master/Slave
configuration, the
Master monitors
the status of the
Slaves in its
network. If a slave
unit fails to be
identified, the
Master will post
this message.
- The scanning
tunnel's no-
read rate
increases.
- More than one
slave unit may
be shown as
not responding.
- In a tunnel
configuration,
the cabling that
connects the
system into to a
network must
be intact or a
scanner will be
reported as not
responding.
- Make sure all the
slave units are
powered on.
- Make sure
cables are
connected.
- Check scanners
power source.
- Replace scanner.
80
Node Reset
Error
In a Master/Slave
configuration, the
Master monitors
the status of the
Slaves in its
network. If a Slave
resets, it sends a
reset message to
the Master. The
Master then posts
this error condition
on the diagnostic
screen.
- The scanning
tunnel's no-
read rate may
increase during
the Slave
scanner's
reconnection.
- This condition is
related to a
slave scanner.
Make sure the
power source of
the slave is not
faulty.
- If condition
persists, replace
the scanner.
81
Motor
Failure
Error
The scanner's
mirror wheel
motor has failed.
- The scanner will
be powered up
but will not
emit laser light
from its exit
window.
- The scanners
motor will not
be spinning.
- Hold your hand
in front of the
scanner to
determine if the
laser is on.
This is an internal
failure and is not
field serviceable
- Replace scanner.
83
Laser Failure
Error
Scanner has a laser
failure.
- There is no laser
light emitted
from the
scanner
- The mirror
wheel motor
may still be
spinning,
however, the
motor speed
may be out of
range at which
time the
scanner will
turn off the
laser light.
- Hold your hand
in front of the
scanner to
determine if the
laser is on.
This is an internal
failure and is not
field serviceable.
- Replace scanner.