ELECTRICAL INSTALLATION
39
3
3.12 TACHOMETER WIRING TO CBX510
DX8210 applications over a conveyor belt use an accessory tachometer and mounting kit.
The following diagrams illustrate standard recommended wiring of an encoder to the CBX510
terminal block.
3.12.1 Encoder/Tachometer Wiring for NPN Output (two models)
Figure 34: OEK-2 Encoder/Tachometer Wiring (NPN Output)
NOTE: Some tachometers may
have a different color coding:
(+V)
Red or White/Orange
(Signal)
White or White/Blue
(Ground) Black or Orange/White