EasyManua.ls Logo

Datalogic DS8110

Datalogic DS8110
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DS8110 REFERENCE MANUAL
18
2
2.5.5 Mounting Structure Considerations
Your first task is to mount your DS8110 barcode scanner. You can provide your own
mounting structure or Datalogic can design one for you. We recommend using a Datalogic
mounting structure for standard applications.
Your mounting structure must provide the following capabilities:
It is adjustable enough for you to move your unit to the optimum position for proper
scanning.
It allows a technician access to the barcode scanner while it is mounted.
It must be as vibration free as possible so as not to affect the scanning accuracy.
It is constructed of steel or aluminum.
It provides approximately 300 mm [12 inches] minimum clearance on all sides. This
clearance is necessary to provide proper ventilation, allow access to all panels of the
barcode scanner, and allow room for proper servicing.

Table of Contents

Related product manuals