INTERNAL NETWORK CONFIGURATIONS
PRODUCT REFERENCE GUIDE
159
The Reading Mask shows which device reads which Expected Code. The mask is com-
posed of a fixed 32-character string (0=No Read or 1=Read) representing the 32 possible
re
aders in an ID-NET network. By default the Master is the last character in the string
(Master on Right) but this can be changed. The Slaves are shown adjacent to the Master
in order (1 to 31), by default from right to left.
Example: Master + Slave 1 = 00000000000000000000000000000011
The
figure above shows that both the Master and Slave 1 are reading Code 128 while
only the Mast
er is reading Code 39.
3. After verifying correct functioning of the reading devices, return the Expected
Code fields fr
om Reading Mask to Code Content.
4. If you haven’t made any other changes you can exit without saving. Otherwise,
sa
v
e the Master device configuration overwriting its previous one, making sure to
save without Clone Master Configuration on Slaves, otherwise the Slave configu-
rations will be overwritten.