About this task
The following images indicate the location of the M.2 2230 solid state drive and provide a visual representation of the removal
procedure.
Figure 73. Removing the M.2 2230 PCIe solid state drive
Steps
1. Loosen the four captive screws that secure the M.2 heat sink to the system board.
2. Lift and remove the M.2 heat sink from the computer.
3. Remove the single (M2x3.5) screw that secures the solid state drive to the system board.
4. Slide and lift the solid state drive off the system board.
NOTE: If the computer has two solid state drives installed, repeat step 3 to step 4 for the second solid state drive.
Installing the M.2 2230 PCIe solid state drive
Prerequisites
If you are replacing a component, remove the existing component before performing the installation procedure.
About this task
The following images indicate the location of the M.2 2230 solid state drive and provide a visual representation of the
installation procedure.
Removing and installing Customer Replaceable Units (CRUs)