6 RASP5 speed controller
6.7 Configuration of specific settings
150 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
The following two tables provide an overview of the conditions under which
the sensors cause the drive to stop
Table 28: Signal detection in Manual mode
Table 29: Signal detection in Auto mode
Manual mode
P1-13 SEN I1 SEN I2 SEN I3 SEN I4
0 – – – –
1 No function No function No function No function
2
No function No function No function No function
3 No function No function No function No function
4 Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
or signal control
No function No function
5
Stop in FWD operation with
edge control
Stop in FWD operation with
edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
6
No function No function No function No function
7 Stop in FWD operation with
edge control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
8
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
or signal control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
Auto mode
P1-13 SEN I1 SEN I2 SEN I3 SEN I4
0 – – – –
1
No function No function No function No function
2 Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
No function No function
3
Stop in FWD or REV operation
with edge or signal control
No function No function No function
4
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
No function No function
5
Stop in FWD operation with
edge or signal control
Stop in FWD operation with
edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
Operation with fixed frequency 1
(f-Fix1) with edge control
6
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
7 Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
8
Stop in FWD operation with
edge or signal control
Stop in REV operation with edge
control
FWD operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control
REV operation with fixed
frequency 1 (f-Fix1) with edge
control or signal control