3 Installation
3.2 Instruction leaflets
86 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
Horizontal arrangement
(base rotated by 90°)
Figure 42: Fixing dimensions (standard) and mounting
Horizontal arrangement, center fixing
(base rotated by 90°)
Figure 43: Fixing dimensions (center)
Two M6 screws, tightening torque 1.3 Nm.
Drill hole with thread for M6 screw.
When using pre-assembled screws, there must be a clearance between the mounting surface and the
washer
of about 12 mm.
Tighten the screws to a torque of 1.3 Nm.
245.0 mm (9.65")
173 mm (6.81")
1
3
2
1
2
3
110 mm (4.33”) 110 mm (4.33”)
245 mm (9.65")