10.3.5.2 Setting
Fig. 10.19 Configuration / Code: Setting
10.3.6 Configuration / Autostart
This function determines whether the pump is set to ‘OFF’ (“Standby” in V 4.0) when the
mains connection is re-established following a power cut or if the pump should immediately
recommence functioning in the configured operation mode.
10.3.6.1 Selecting
Fig. 10.20 Configuration / Autostart: Selecting
- autostart is inactive.
When the mains voltage is
connected, the pump always
enters the "OFF" (“Standby“ in V
4.0) operating state.
(Default setting)
autostart is active.
When the mains voltage is
connected, the pump starts
functioning in the configured
operation state.
10.3.7 Configuration / Metering lock
If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II (or at plug VII or plug VIII, if a dongle box is used) between PINS 3+ 4
and an external enable contact is connected (electrical connection see chapter
7.2.3.3,
8.2.3.2
and 8.2.4.3). The selected operating mode does not affect the use of the metering
lock.
10.3.7.1 Selecting
Fig. 10.21 Configuration / Metering lock: Selecting
- Interrogation of the metering lock
is inactive. (Default setting)
Interrogation of the metering lock
is active.

Table of Contents

Other manuals for Ecolab Elados EMP II E60

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab Elados EMP II E60 and is the answer not in the manual?

Ecolab Elados EMP II E60 Specifications

General IconGeneral
BrandEcolab
ModelElados EMP II E60
CategoryWater Pump
LanguageEnglish

Related product manuals