9.7 Delivery condition
9.7.1 Basic setting of the mode of operation / display in the operating display
On delivery, the mode of operation internal is displayed in the version “display/ strokes”.
Therefore, the following parameters are shown on the display when the main voltage is
switched on.
Metering frequency / - quantity: strokes / min (122 strokes / min at 50 Hz,
146 H strokes / min at 60 Hz)
Operating state: OFF (at V 4.1, „Standby“ at V4.0)
(to start the pump press START / STOP key)
Fig. 9.8 Basic setting of the mode of operation / display in the operating display
With each stroke of the pump, the indicator in the upper right of the display rotates 1 turn.
9.7.2 Basic settings in the configuration
The following factory settings are defined in the configuration.
Fig. 9.9 Basic settings in the configuration
Configuration of Standard see Chapter
language: German 10.3.3
unit: litre
10.3.4
code: not active (-) 10.3.5
auto start: not active (-)
10.3.6
metering lock: not active (-)
10.3.7
low level contact: open ()
10.3.8
alarm output: off (
) 10.3.9
pulse memory: not active (-)
10.3.10
oval gear meter: not active (-)
10.3.11
metering controler: not active (-)
10.3.12
meter monitor: not active (-) 10.3.13
microflow: not active (-)
10.3.14
batch: not active (-) 10.3.15
degas: not active (-) 10.3.16
microflow Only appears on the display in conjunction with the
MicroFlow
PLUS
metering monitor, which is available as an
accessory.