EasyManua.ls Logo

Ecolab Elados EMP II E60 - Technical Specification Tables

Ecolab Elados EMP II E60
218 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
417101438_EMPII_E60.docx
- 136 -
Rev. 11-02.14
14.3 Technical specifications "Overview tables"
Description
Pump type
V3014
V3025
00048 00043
00072
00112 00240
0,6 MPa
1 MPa
Supply voltage
230 V / 50/60 Hz ± 10 % (special voltages on request)
max. current input 115V 50/60 Hz
230V 50/60 Hz
0.12 A
0.06 A
0.20 A
0.21 A
0.09 A
0.29 / 0.33 A (0.7 A)*
0.14 / 0.16 A (0.7 A)*
Motor Power 115/230V 50/60 Hz
10.4 / 11.5 W
18.7 W
19.8 W
30 / 34.5 W (25 W)*
Fuse rating 115 V
230 V
315 mA (1A)*
Type of protection
IP 65
Breaking capacity at circuit with 24 V
Empty report output: 24 V 3 A AC/DC
stroke signal output: 24 V 0.3 A DC
Breaking capacity at circuit with 230 V
Empty report output: 230 V / 3 A AC/DC
stroke signal output: connection according to VDE is not permitted
* The values at brackets refer to types 00072, 00112, 00240 with BLDC- Motor
(visible at the voltage indication 100- 240V at identification plate)
14.3.1 General data - Standard pumps
Description
Pump type
V3014
V3025
00048
00043
00072
00112
00240
0,6 MPa
1 MPa
Pump output [l/h]* / **
1.4
2.5
4.8
4.3
7.2
11.2
24
max. metering backpressure [MPa (bar)]**
0.1 (10)
0.4 (4)
1 (10)
0.6 (6)
1 (10)
0.5 (5)
0.2 (2)
Number of strokes [1/min] at 50 Hz
122
Metering quantity/stroke [ml] 50 Hz/60 Hz
0.19
0.34
0.65
0.57
0.98
1.5
3.28
Metering accuracy [see chapter 14.4]
< ± 3%
max. conveyable viscosity [mPas]
200
Permitted ambient temperature
5-40°C
Suction height [mWs] at 100 % stroke***
2
max. pre-pressure suction sided [MPa (bar)]
0.08 (0.8)
0.05 (0.5)
0.02 (0.2)
Noise level [DBA] at 1 m distance
(acc. to DIN EN 12639/ EN ISO 9614-2)
54
Recommended minimum diameter of
suction/pressure connector [ID mm]
4 6
Weight [kg]
2
2.4
3.1
3.3
* All data relate to water at 20 °C
** At mains power frequency of 60 Hz, the delivery capacity increases by 20%, while metering backpressure decreases by 20%.
*** Suction heights with clean, moistened valves at 100% metering stroke and max. stroke frequency
14.3.2 Deviant general data - Pumps in the “Higher Pressures (HP)” version
Description
Pump type
V3014
V3025
00043
Pump output [l/h]*
1.2
2
4
max. metering backpressure [MPa (bar)]
1.6 (16)
Metering quantity/stroke [cm³]
0.16
0.27
0.55
* all data relate to water at 20 °C
14.3.3 Materials
Pump head: PVDF, optionally PP, stainless steel 1.4571
Diaphragm: PTFE-EPDM composite diaphragm
Seals: FPM (Viton B), optionally EPDM, Kalrez
Valves: PVDF, optionally PP or stainless steel 1.4571
Ball valves: Ceramic, optionally stainless steel 1.4401, PTFE
Housing: thermoplastic polyester
Colour: Blue RAL 5007
Special versions available on request.

Table of Contents

Other manuals for Ecolab Elados EMP II E60

Related product manuals