10.3.12.2 Display in the operating display with an active metering controller
▼ = Downward metering divergence
The pump is currently delivering less than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is increased automatically until the actual value
matches the target value.
Fig. 10.30 Display in the operating display with an active metering controller: Downward metering divergence
- = No metering divergence
The pump delivers exactly the preset flow (here 100/min for example).
No correction is necessary.
Fig. 10.31 Display in the operating display with an active metering controller: no metering divergence
▲ = Upward metering divergence
The pump is currently delivering more than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is reduced automatically until the actual value
matches the target value.
Fig. 10.32 Display in the operating display with an active metering controller: Upward metering divergence
NOTE
Oval gear meter OGM
PLUS
mounted.
10.3.13 Configuration / Metering monitoring
If the metering monitoring function is enabled, the pump strokes are compared to the
incoming pulses using a connected external metering monitor (e.g. oval gear meter). If a
configurable tolerance threshold is breached, an alarm is triggered.
The metering monitoring system can be connected at plug II (or plug V if a dongle box is
used) at Pin 2+4 (input pulse) or at Pin 3+4 (input metering lock) (assortment of inputs see
chapter 10.3.13.5
“Metering monitoring / Input (only at E60 WITHOUT Dongle box)”, electrical
connection see chapter
7.2.3.5 “Installing the metering monitoring” and 8.2.1.1 “Installation
oval gear meter (OGM or OGM
PLUS
)”).
NOTE
If an oval gear meter is connected as a metering monitoring unit and should be
correspondingly evaluated, then the configuration/oval gear meter function must be
enabled in addition to the configuration/metering monitoring function (see chapter 10.3.11).
10.3.13.1 Selecting
Fig. 10.34 Configuration / Metering monitoring: Selecting
- metering monitoring is inactive.
(Default setting)
metering monitoring is active.
On activating metering monitoring, a
submenu appears with the following
menu items:
Menu item see chapter
• Stop pump 10.3.13.2
• Strokes
10.3.13.3
• Deviation
10.3.13.4