10.3.10.1 Selecting
Fig. 10.24 Configuration / pulse memory: Selecting
- pulse memory is inactive.
(Default setting)
pulse memory is active.
10.3.10.2 Display in the operating display with an active pulse memory
Meaning Pos Description
Pulse multiplication
(Example: 10 external pulses
become 20 strokes)
Number of pulses received
Fig. 10.25 Display in the operating display with an active pulse memory:
pulse multiplication
Pulse division
(Example: 10 external pulses
become 20 strokes)
Fig. 10.26 Display in the operating display with an active pulse memory:
pulse division
10.3.11 Configuration / Oval gear meter (only E60
PLUS
& OGM
PLUS
)
The oval gear meter function makes it possible to record a “real” value in the operating
data/liter menu item (see chapter
10.5.3). Furthermore, this menu item must be enabled to
use the metering controller function (see chapter
10.3.12).
The function oval gear meter can only be activated if the pump is upgraded with a Dongle-
Box (Art. No.248606, EBS No. 10016094) to the E60
PLUS
and an OGM
PLUS
(oval gear meter
see Accessories) is connected.
To activate the Dongle-Box in connection with the oval gear meter, the power supply has to
be switched off and on again! (Unplug power plug or switch the pump off and back on again!)
If the dongle box is fitted and is activated by switching the pump off and then on again,
"E60+" appears on the bottom left of the pump's display unit. If an OGM
PLUS
(oval gear
meter) is connected to slot V on the dongle box and is activated by switching the pump off
and then on again, "E60++" appears on the pump's display unit, and the oval gear meter
function is automatically enabled under “Configuration” in the pump menu and the function
dosing regulator can be selected now.
If the pump software recognises that there is a dongle box or an OGM
PLUS
connected, and
the communication is then interrupted between the pump and the periphery unit (e.g. through
the removal of the unit), an error message is displayed (see chapter
12.2 “Alarm messages
(display)”). To prevent this error message appearing repeatedly, the communication
(connection) must be restored, or the analysis must be disabled in the pump software.
(see capter 12.2.1
„Deactivating of the dongle box or OGM
PLUS
in the pump software“).