10.3.14.1 Selecting
Fig. 10.40 Configuration MicroFlow
PLUS
- MicroFlow
PLUS
is inactive.
(Default setting)
PLUS
On activating MicroFlow
PLUS
, a
submenu appears with the following
menu items:
Menu item see chapter
• Stop pump 10.3.14.2
• Strokes
10.3.14.3
• Deviation
10.3.14.4
• Metering break
10.3.14.5
• Metering delay
10.3.14.6
10.3.14.2 MicroFlow
PLUS
/ Stop pump
Fig. 10.41 Configuration MicroFlow
PLUS
/ Stop pump
The “stop pump” function is used
to set whether or not the pump
stops if a “metering monitoring
alarm” is triggered.
- Pump is not stopped in the
event of an „Alarm metering
monitor function“
(Default setting)
Pump is stopped in the event
of an „Alarm metering monitor
function“
10.3.14.3 MicroFlow
PLUS
/ Strokes
Fig. 10.42 Configuration MicroFlow
PLUS
/ Strokes
The "Strokes" option is used to
specify the interval of strokes to
be monitored.
Setting range: 0-100
Default setting = 10 strokes