10.3.14.4 MicroFlow
PLUS
/ Deviation
The "Deviation" option is used to specify the number of undetected strokes permitted during
the stroke interval to be monitored (see chapter
10.3.14.3 "MicroFlow
PLUS
/ Strokes") before
the metering monitoring function issues an alarm.
Fig. 10.43 Configuration MicroFlow
PLUS
/ Deviation
Example: Strokes 40, deviation 20
This example accepts 20
undetected strokes in an interval
of 40 strokes. An alarm is issued if
21 strokes are undetected.
Setting range: 0-100
Default setting = 40
10.3.14.5 MicroFlow
PLUS
/ Metering break
When handling media with a tendency to emit gas, gas bubbles form in the system after
extended downtimes, resulting in corrupted volume values of the quantity to be metered and
subsequently to the non-detection of the metering strokes by the MicroFlow
PLUS
and the
issuance of an alarm.
Fig. 10.44 Configuration MicroFlow
PLUS
/ Metering break
“Metering break” is used to set the
period without metering after which
the monitoring system is
deactivated for a specific time (see
chapter
10.3.14.6MicroFlow
PLUS
/
Metering delay) to prevent the
undesired activation of the
monitoring system.
Setting range: 2 - 3600s
Default setting = 240 sec.

Table of Contents

Other manuals for Ecolab Elados EMP II E60

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab Elados EMP II E60 and is the answer not in the manual?

Ecolab Elados EMP II E60 Specifications

General IconGeneral
BrandEcolab
ModelElados EMP II E60
CategoryWater Pump
LanguageEnglish

Related product manuals