Patient Monitor User Manual Managing Patients
- 81 -
6.5 Central Monitoring System
The monitor can be connected to the central monitoring system. Through the network:
1. The monitor sends patient information, real-time monitoring or measurement data to the
central monitoring system.
2. The real-time monitoring information is displayed on the central monitoring system as the
same to the monitor, and the central monitoring system can perform some bilateral control.
For example: changing patient information, receiving patient, discharging patient and so
forth.
For detailed information, please refer to MFM-CMS Central Monitoring System User Manual.
And the monitor supports HL7 protocol.
NOTE:
1 Use wired instead of wireless networking when connecting the monitor to central
monitoring system in the operating room because the ESU will interfere with a
wireless network, which may cause networking failure.
2 Make sure the network connection between the monitor and MFM-CMS is in good
condition when the time synchronization function on the monitor is active. (Default
setting is off. Setting path: Menu > Maintenance > User Maintain > Date/Time
Setup > Sync Time). If the setting is on, the monitor will accept time synchronization
from MFM-CMS.
3 The time synchronization function might not be available to all software versions of
MFM-CMS. Consult our technical service department or your local distributor for
more information.
4 When the monitor is connected to MFM-CMS (V2.64 above) and Gateway (V1.1
above), user should turn on Transmission Encryption function through User
Maintain > Other Setups > Transmission Encryption to validate it. When the
monitor is connected to MFM-CMS (V2.64 or below) and Gateway (V1.1 or below),
the monitor’s Transmission Encryption function should be turned off. To ensure
security, upgrade MFM-CMS and Gateway to the latest version.
5 Prior to connecting the monitor to MFM-CMS, please select Menu > Maintenance >
Network Maintain > ProtocolVersion > 2.0+ to ensure the stability and reliability of
the communication.
6 When deploying the network of the monitor and MFM-CMS, it is recommended to
isolate the network and the Intranet system of the hospital by using VLAN so as to
ensure the network security.