Half-Duplex to Full-Duplex Converter Environmental Data and Standards
Table 288: Environmental Data
Environmental conditions Operating temperature: -40°C to 70°C (-40°F to 158°F)
Storage temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 10% to 95% relative humidity, non-condensing
Altitude: 0 to 2,000 meters (6,562 feet)
Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks
Packaged vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500 Hz at 0.2
G
Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct. from
20 to 200 Hz
Packaged drop height: 14 drops minimum on sides and corners at 42
inches (<15 kg box)
Table 289: Safety Standards
North American ITE UL 60950-1 2nd Ed., Listed Device (U.S.)
CSA 22.2 #60950-1-03 2nd Ed. (Canada)
Complies with FCC 21CFR 1040.10 (U.S. Laser Safety)
European/International ITE EN 60950-1:2007 2nd Ed.
CB Report & Certificate per IEC 60950-1 2nd Ed. + National Dierences
AS/NZS 60950-1 (Australia /New Zealand)
EMI/EMC Standards FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
EN 55022: Class A
EN 55024:A2 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2,8 (Harmonics)
EN 61000-3-3 (Flicker)
2014/30/EU EMC Directive
International EMC
Certifications
CISPR 22: Ed 5.2, Class A (International Emissions)
CISPR 24:A2: Class A (International Immunity)
IEC 61000-4-2: EN 61000-4-2:2009 Electrostatic Discharge, 8kV
Contact, 15 kV Air, Criteria A
IEC 61000-4-3: EN 61000-4-3:2006+A1:2008 Radiated Immunity
10V/m, Criteria A
IEC 61000-4-4: am1 ed.2./EN 61000-4-4:2004/A1:2010 Transient Burst,
1 kV, Criteria A
IEC 61000-4-5: EN 61000-4-5:2006 Surge, 2 kV L-L, 2 kV L-G, Level 3,
Criteria A
IEC 61000-4-6: EN 61000-4-6:2009 Conducted Immunity, 0.15-80
MHz, 10V/m unmod. RMS, Criteria A
IEC/EN 61000-4-11: Power Dips & Interruptions, >30%, 25 periods,
Criteria C
IEEE 802.3 Media Access
Standards
IEEE 802.3ab 1000BASE-T
IEEE 802.az EEE
Environmental specifications EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
ASTM D3580 Random Vibration Unpackaged 1.5 G
Half-Duplex to Full-Duplex Converter Environmental
Data and Standards Technical Specifications
452 ExtremeSwitching Hardware Installation Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks ExtremeSwitching X435 Series and is the answer not in the manual?

Extreme Networks ExtremeSwitching X435 Series Specifications

General IconGeneral
BrandExtreme Networks
ModelExtremeSwitching X435 Series
CategorySwitch
LanguageEnglish

Related product manuals