Displaying PoE Settings and Statistics
ExtremeWare XOS 11.3 Concepts Guide
175
Displaying System Power Data
Additionally, you can view the distribution of power, as well as currently required and allocated power,
on the entire switch including the power supplies by using the following command:
show power budget
Following is sample output from this command:
PS State Watts 48V 12V
---------------------------------------------------------------------------
1 Powered On 1152.00 1104.00 48.00
2 Powered On 1152.00 1104.00 48.00
3 Empty
4 Empty
5 Empty
6 Empty
---------------------------------------------------------------------------
Power Available: 2304.00 2208.00 96.00
Redundant (N+1) Power Available: 1200.00 1152.00 48.00
Slots Type State Watts 48V 12V
---------------------------------------------------------------------------
Slot-1 Empty
Slot-2 Empty
Slot-3 G48P Operational 111.00 110.00 1.00
Inline Power (budgeted + 2% loss) 51.00 51.00 0.00
Slot-4 G48P Empty
Slot-5 G8X Operational 0.00 0.00 0.00
Slot-6 G48T Operational 0.00 0.00 0.00
Slot-7 G48P Operational 111.00 110.00 1.00
Inline Power (budgeted + 2% loss) 51.00 51.00 0.00
Slot-8 Empty
Slot-9 Empty
Slot-10 Empty
MSM-A MSM-G8X Operational 151.00 150.00 1.00
MSM-B Empty 151.00 150.00 1.00
FanTray Operational 55.00 55.00 0.00
---------------------------------------------------------------------------
Power Required: 681.00 677.00 4.00
Power Allocated: 681.00 677.00 4.00
Power Surplus: 1623.00 1531.00 92.00
Redundant Power Supply(s) Present?: yes
The term 2% loss shown in this display is the 2% associated with powering PDs. For example, when
you reserve 50 W for a particular slot, the system reserves 51 W.