Displaying PoE Settings and Statistics
ExtremeWare XOS 11.3 Concepts Guide
177
● Total ports faulted—Displays the number of ports in a fault state.
● Total ports disabled—Displays the number of ports in a disabled state.
Following is sample output from this command:
Inline-Power Slot Statistics
Slot: 3
Firmware status : Operational
Firmware revision : 292b1
Total ports powered : 17
Total ports awaiting power : 31
Total ports faulted : 0
Total ports disabled : 0
Displaying Port PoE Information
You can display PoE configuration, status, and statistics per port.
Displaying Port PoE Configuration
Use the following command to display PoE configuration for each port:
show inline-power configuration ports <port_list>
This command provides the following information:
● Config—Indicates whether the port is enabled to provide inline power:
â– Enabled: The port can provide inline power.
â– Disabled: The port cannot provide inline power.
● Operator Limit—Displays the configured limit, in milliwatts, for inline power on the port.
● Priority—Displays inline power priority of the port, which is used to determine which ports get
power when there is insufficient power for all ports requesting power:
â– Low
â– High
â– Critical
● Label—Displays a text string, if any, associated with the port (15 characters maximum).
Following is sample output from this command:
Port Config Operator Limit Priority Label
3:1 Enabled 15000 mW Low
3:2 Enabled 15000 mW Low
3:3 Enabled 15000 mW Low
3:4 Enabled 15000 mW Low
3:5 Enabled 15000 mW Low
3:6 Enabled 15000 mW Low
3:7 Enabled 15000 mW Low
3:8 Enabled 15000 mW Low
3:9 Enabled 15000 mW Low
3:10 Enabled 15000 mW Low