Status Monitoring and Statistics
ExtremeWare XOS 11.3 Concepts Guide
196
The following sample output displays the current temperature and operating status of the installed
modules and power controllers:
Field Replaceable Units Temp (C) Status
------------------------------------------------
Slot-1 : 10G6X 36.37 Normal
Slot-2 : G60X 35.31 Normal
Slot-3 :
Slot-4 :
Slot-5 :
Slot-6 : G60X 34.68 Normal
Slot-7 : G60X 34.31 Normal
Slot-8 :
MSM-A : MSM-1XL 31.37 Normal
MSM-B : MSM-1XL 29.75 Normal
PSUCTRL-1 :
PSUCTRL-2 : 29.00 Normal
Temp Range: -10.00 (Min), 0.00-50.00 (Normal), 60.00 (Max)
The switch monitors the temperature of each component and generates a warning if the temperature
exceeds the normal operating range. If the temperature exceeds the minimum/maximum limits, the
switch shuts down the overheated module.
System Temperature Output—Summit X450 Switch Only
On a Summit X450 switch, the output includes the current temperature and operating status of the
switch and the XGM-2xn card.
The following sample output displays the current temperature and operating status of the switch:
Field Replaceable Units Temp (C) Status
------------------------------------------------
Switch : SummitX450-24x 42.50 Normal
XGM-2xn-1 :
Temp Range: -10.00 (Min), 0.00-60.50 (Normal), 62.90 (Max)
The switch monitors its temperature and generates a warning if the temperature exceeds the normal
operating range. If the temperature exceeds the maximum limit, the
show switch output indicates the
switch in an
OPERATIONAL (Overheat) mode, and the show temperaturee output indicates an error
state due to overheat.
Power Supply Temperature—Modular Switches Only
To view the current temperature of the power supplies installed in a BlackDiamond 10K switch or the
BlackDiamond 8800 family of switches, use the following command:
show power {<ps_num>} {detail}
The following sample output displays the temperature information:
PowerSupply 1 information:
...