EasyManua.ls Logo

Fluke Wavetek-Datron 395 - Resuming Local Operation

Fluke Wavetek-Datron 395
285 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
"Noise calculations,
waveform
too large",................. Error code
55
"Bandwidth>
10MHz",................................................. Error code
56
"Function canceled", Error code
57
"Noise sequence length
too
long for function", Error code 58
"Pulse delay is too negative", Error code
59
"Trigger
count
>524287 for sequence
not
allowed",. Error code
60
"Selected attenuator causes lower
amplitude
and
offset",
............................................................................................ Error code
61
"Frequency
span
(carrier/ modulation) too
high"
,.... Error code
62
"Function
not
allowed
as
signal",........... Error code 63
"Frequency too
high
for
AM/FM",
Error code 64
"Function
setup
error",.................................................. Error code
65
"Cannot
use
selected function as signal",................... Error code
66
"Internal Execute Error",............................................... Error code 67
"Maximum
number
of
waveforms
have
been
defined",
............................................................................................ Error code
68
Noise
"Function: <NAME>
not
allowed as signal"
Pulses
1Pulse Trains
"Pulse <1..10>, <delay,lead,width,trail>
s/b
"greater
or
less
than"
<limit> for this
period
range"
"Pulse
<LlO>,
width
too
small
for
lead/trail,
must
be
>limit"
"Pulse <1..10>,
delay
+
lead
+
width
+ trail >
period"
"Pulse <1..10>,
delay
+
lead
+
width
+ trail >
period"
5.11
RESUMING LOCAL OPERATION
When the GPIB
or
RS-232-C interface has remote control
of
the Model 395, your front
panel operator controls will function only to query, and not set, parameter values (even
then, only
when
there is
no
bus
activity).
When
you
discontinue
remote
interface
operations, you will not have local control returned to you unless the remote application
has specifically sent a Go
To
Local (lEEE-488.1 ASCII GTL) code.
If
you find that yon
do
not
have
local
control
after
a
remote
programming
session,
you
will
have
to
manually return to local control. To
do
fuis,
press the "Remote" key and select "go-local."
This could also
be
accomplished by cycling power
to
the Model 395.
5-58 Remote Operation