"Disconnecting the power cord" on page 47
.
â–¶
"Getting access to the component" on page 49.
â–¶
"Removing the air duct" on page 65.
Removing the defective heat sink
â–¶
Remove the heat sink, see "Removing the heat sink" on page 233.
â–¶
Remove the residual thermal paste from the CPU surface.
â–¶
Clean the CPU surface using a lint-free cloth.
Installing the new heat sink
â–¶
Remove the protective cover on the underside of the new heat sink.
CAUTION
â–¶
Do not touch the thermal paste on the underside of the heat sink.
â–¶
Install the heat sink, see "Installing the heat sink" on page 240
.
Concluding steps
â–¶
"Installing the air duct" on page 66.
â–¶
"Reassembling" on page 53.
â–¶
"Connecting the power cord" on page 57.
â–¶
"Switching on the server" on page 60.
â–¶
If applicable, "Installing the front cover with lock" on page 61.
Processor (CPU)
242 Upgrade and Maintenance Manual RX1330 M5