Chapter 8 - Replacement Procedures 8-21
Section 8-9
Replacement of Monitor
8-9-1 Manpower
2 people, 10 minutes
8-9-2 Tools
Philips screwdriver, Allen Wrench
8-9-3 Remove Procedure
1.) Open the LCD LID COVER. Refer to the figure below.
2.) Loosen the cable screw. Refer to the figure below.
3.) One person to grab the MONITOR and not to drop it. Other to the persons should unscrew the 2
hexagonal socket screws and then separate hte MONITOR for the MONITOR STAND ARM. Refere
to the figure below.
Figure 8-22 Removing the LCD COVER
Figure 8-23 Loosining the Monitor Cable screw
LCD Cover
Unscrew the fastener and disconnect
the cable
Unscrew 2 fasteners
Unscrew fastener and remove
LCD cable clamp