UCM6200 Series User Manual
channel. In other words, this number serves as the maximum number of CC requests
this channel is allowed to make. The minimum value is 1.
CC Max Monitors
Configure the maximum number of monitor structures which may be created for this
device. In other words, this number tells how many callers may request CC services
for a specific device at one time. The minimum value is 1.
Ring Simultaneously
Ring
Simultaneously
Enable this option to have an external number ring simultaneously along with the
extension. If a register trunk is used for outbound, the register number will be used to
be displayed for the external number as caller ID number.
External Number
Set the external number to be rang simultaneously. ‘-’ is the connection character
which will be ignored.
Time Condition for
Ring
Simultaneously
Ring the external number simultaneously along with the extension on the basis of this
time condition.
Monitor privilege control
Allowed to call-
barging
Add members from “Available Extensions” to “Selected Extensions” so that the
selected extensions can spy on the used extension using feature code.
Seamless transfer privilege control
Allowed to
seamless transfer
Any extensions on the UCM can perform seamless transfer. When using Pickup Incall
feature, only extensions available on the “Selected Extensions” list can perform
seamless transfer to the edited extension.
Other Settings
Ring Timeout
Configure the number of seconds to ring the user before the call is forwarded to
voicemail (voicemail is enabled) or hang up (voicemail is disabled). If not specified,
the default ring timeout is 60 seconds on the UCM6200, which can be configured in
the global ring timeout setting under web GUI->Internal Options->IVR Prompt:
General Preference. The valid range is between 5 seconds and 600 seconds.
Note: If the end point also has a ring timeout configured, the actual ring timeout used
is the shortest time set by either device.
Auto Record
Enable automatic recording for the calls using this extension. The default setting is
disabled. The recording files can be accessed under web GUI->CDR->Recording
Files.
Skip Trunk Auth
If set to “yes”, users can skip entering the password when making outbound calls.
If set to “By Time”, users can skip entering the password when making outbound
calls during the selected time condition.
If set to “No”, users will be asked to enter the password when making outbound
calls.
Time Condition for
Skip Trunk Auth
If ‘Skip Trunk Auth’ is set to ‘By Time’, select a time condition during which users can
skip entering password when making outbound calls.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks UCM6206 and is the answer not in the manual?

Grandstream Networks UCM6206 Specifications

General IconGeneral
BrandGrandstream Networks
ModelUCM6206
CategoryIP Phone
LanguageEnglish

Related product manuals