December 2001 DSP Error Messages NC Software 280 470-xx, 280 472-xx, 280 474-xx 10 – 3
10 Error Messages
10.1 DSP Error Messages NC Software 280 470-xx, 280 472-xx, 280 474-xx
10.1.1 Non-Axis-Specific DSP Error Messages with Error Code
Error message Cause of error, corrective action As of
NC SW
DSP ERROR FF01 Undefined error, no traceable cause (data processing error) 280 470-01,
280 472-01,
to
280 474-03
DSP ERROR FF02 Host command not recognized, not valid (data processing
error)
DSP ERROR FF03 Host and DSP watchdogs disagree (data processing error)
DSP ERROR FF04 Undefined interrupt (data processing error)
DSP ERROR FF05 Unknown hardware ID (hardware and software
incompatible)
DSP ERROR FF06 No V_NOML value received from host (data processing
error)
DSP ERROR FF07 AC fail (power module error)
DSP ERROR FF09 Stack overflow (data processing error)
DSP ERROR FF0A Triangular signal pulse-width modulation (hardware
problem or wrong value in MP2180)
DSP ERROR FF0B Error upon memory request (data processing error)
DSP ERROR FF0C No velocity control interrupt (data processing error)
DSP ERROR FF0D Checksum error, code (data processing error)
DSP ERROR FF0E Timeout of the speed interrupt (data processing error)
DSP ERROR FF0F Error when initializing a software timer (data processing
error)
DSP ERROR FF10 Error during LSV2 transmission (data processing error)
DSP ERROR FF11 Drive start without previous synchronization (data
processing error)
DSP ERROR C001 Undefined error, no traceable cause (data processing error) 280 474-04
DSP ERROR C002 Host command not recognized, not valid (data processing
error)
DSP ERROR C003 Host and DSP watchdogs disagree (data processing error)
DSP ERROR C004 Undefined interrupt (data processing error)
DSP ERROR C005 Unknown hardware ID (hardware and software
incompatible)
DSP ERROR C006 No V_NOML value received from host (data processing
error)
DSP ERROR C007 AC fail (power module error)
DSP ERROR C009 Stack overflow (data processing error)