EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - Module 9123 Traversing the Reference Marks of PLC Axes; Module 9124 Feed Rate Override for PLC Axis

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
December 2001 PLC Axes 6 31
Module 9123 Traversing the reference marks of PLC axes
Traverse the reference marks as for NC axes.
n You can use the same procedure to traverse a reference mark for PLC axes
as for NC axes. Use Module 9123 only if no conventional procedure is
possible.
n Module 9123 moves the axis in the given direction until the reference mark
has been traversed. The axis stops next to the reference mark, offset by the
braking path.
Call:
PS B/W/D/K <Axis>
0 to 8 correspond to axes 1 to 9
PS B/W/D/K <Feed rate>
Input unit: [mm/min]
PS B/W/D/K <Mode>
Bit 0: Direction of traverse
0: Positive
1: Negative
CM 9123
PL B/W/D <Error code>
0: No error. Positioning was started.
1: Axis does not exist
2: Not a PLC axis
3: Axis is already being positioned
5: Programmed axis not in closed loop
6: Feed rate not permitted
Module 9124 Feed rate override for PLC axis
Enters the feed rate override for one PLC axis.
Conditions:
n After interruption of a PLC program, the override value is set to 100%.
n When a positioning is started, the last defined override value is in effect.
n The override value can also be changed during a positioning movement.
Call:
PS B/W/D/K <Axis>
0 to 8 correspond to axes 1 to 9
PS B/W/D/K <Override>
Input unit: 0 to 10 000, corresponds to 0 to 100%
in 0.01% steps
CM 9124
PL B/W/D <Error code>
0: No error, override value was set
1: Axis does not exist
2: Not a PLC axis
3: Override value incorrect

Table of Contents