December 2001 List of Machine Parameters 4 – 71
4.3.18 Second Spindle
Bit 5 – AUTOSTART soft key
0: Do not display soft key
1: Display soft key
Bit 6 – Display of pallet table and NC program
0: Both simultaneously in a split screen
1: Pallet table or NC program individually
Bit 7 – AUTOSTART function by PLC
0: AUTOSTART function performed by the NC
1: AUTOSTART function of an NC program is
performed by the PLC. The NC does not trigger
an NC start.
MP7690 MEMORY TEST during switch-on
Format: %xxx
Input: 1: No MEMORY TEST during switch-on
0: MEMORY TEST during switch-on
Bit 0 – Test the RAM
Bit 1 – Test the EPROM
Bit 2 – Test the hard disk
6 – 326
MP Function and input Software
version and
behavior
Page
MP Function and input Software
version and
behavior
Page
MP13010 to
MP13520
Machine parameter block for the second spindle
Input: Function and input range are identical with
MP3010 to MP3520.
280 474-03 6 – 216