EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - Module 9192 Reading the Operating Times; Module 9193 Setting the Operating Times

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 330 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9192 Reading the operating times
You read the current value of an operating time. The current value is
transferred in seconds. If the value is greater than 2 147 483 648 (approx. 69
years), a negative number will be transferred.
Call:
PS B/W/D/K <Number of the operating time>
3: TNCTIME
2: MACHINETIME
1: PROGTIME
0 to 7: PLCTIME0 to PLCTIME7
CM 9192
PL B/W/D <Current time [s]>
1: Error
Error recognition:
Module 9193 Setting the operating times
You overwrite the current value of the operating time. The old value is lost
irretrievably.
The time for control on (TNCTIME) cannot be overwritten.
Transfer all values greater than 2 147 483 648 (approx. 69 years), as negative
numbers.
Call:
PS B/W/D/K <Number of the operating time>
2: MACHINETIME
1: PROGTIME
0 to 7: PLCTIME0 to PLCTIME7
PS B/W/D/K <New time [s]>
CM 9193
Error recognition:
Marker Value Meaning
M4203 0 PLC operating time started
1 Incorrect transfer value, or module was not called in a
spawn job or submit job
Marker Value Meaning
M4203 0 Operating time was overwritten
1 Incorrect transfer value, or module was not called in a
spawn job or submit job