December 2001 List of Machine Parameters 4 – 31
4.3.6 Spindle
MP Function and input Software
version and
behavior
Page
MP3010 Output of speed, gear range
Input: 0: No output of spindle speed
1: Speed code if the speed changes
2: Speed code at every TOOL CALL
3: Nominal speed value always,
G code if the gear range shifts
4: Nominal speed value always,
G code at every TOOL CALL
5: Nominal speed value always, no G code
6: Same as 3,
but with servo-controlled spindle for oriented
spindle stop
7: Same as 4,
but with servo-controlled spindle for oriented
spindle stop
8: Same as 5,
but with servo-controlled spindle for oriented
spindle stop
PLC
RESET
6 – 180
MP3011 Function of analog output S, if MP3010 < 3
Input: 0: No special function
1: Voltage is proportional to the current
contouring feed rate, depending on MP3012
2: Voltage is defined as through Module 9130
3: Voltage is defined through M functions
(M200 to M204)
RESET 6 – 452
MP3012 Feed rate from output of an analog voltage of 10 V,
MP3011 = 1
Input: 0 to 300 000 [mm/min]
6 – 452
MP3013.x Characteristic curve kink points (velocity) for output of the
analog voltage with M202
Input: 10 to 300 000 [mm/min]
PLC
RUN
6 – 453
MP3014.x Characteristic curve kink points (voltage) for output of the
analog voltage with M202
Input: 0.000 to 9.999 [V]
PLC
RUN
6 – 453
MP3020 Speed range for S code output
Format: xxyyz
xx: S code for minimum speed
yy: S code for maximum speed
z: Speed increment
Input: 0 to 99 999
PLC 6 – 194