6 – 300 HEIDENHAIN Technical Manual TNC 426, TNC 430
6.13.17 End of Program Run
If the program end is reached in the operating modes PROGRAM RUN,
SINGLE BLOCK and PROGRAM RUN, FULL SEQUENCE, the NC sets M4170.
This marker is reset with the next program start.
You can evaluate the information “program end” during program run with
pallet changers, for example.
6.13.18 Files
The TNC enables you to edit various file types. File types are designated with
an extension after the file name. A file name can consist of up to eight
characters (letters and numbers).
Disable soft keys for
file types
With the SELECT TYPE soft key you can display a soft key for each file type:
7
77
7 Select MP7224.0 to disable soft keys of specific file types.
Disabling file types
for editing
Protected files cannot be edited or changed:
7
77
7 Choose with MP7224.1 the files that you want to protect.
Protected files are displayed in the file overview with the color defined in
MP7354.1 or MP7355.1.
MP7224.0 Disabling soft keys for file types
Format: %xxxxxxxx
Input: Bit 0 – HEIDENHAIN programs .H
Bit 1 – ISO programs .I
Bit 2 – Tool tables .T
Bit 3 – Datum tables .D
Bit 4 – Pallet tables .P
Bit 5 – Text files .A
Bit 6 – HELP files .HLP
Bit 7 – Point tables .PNT
0: Do not disable
1: Disable
MP7224.1 Protecting file types
Format: %xxxxxxxx
Input: Bit 0 – HEIDENHAIN programs .H
Bit 1 – ISO programs .I
Bit 2 – Tool tables .T
Bit 3 – Datum tables .D
Bit 4 – Pallet tables .P
Bit 5 – Text files .A
Bit 6 – HELP files .HLP
Bit 7 – Point tables .PNT
0: Do not protect
1: Protect
Set Reset
M4170 END PGM, M02 or M30 was executed NC NC