EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - Logging Measurements by Manual Touch Probe Cycles; File Names of the Individual Print Masks; Format of the Print Masks

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 354 HEIDENHAIN Technical Manual TNC 426, TNC 430
6.15.2 Logging Measurements by Manual Touch Probe Cycles
For every manual touch probe cycle there is one print mask per language.
Standard print masks are saved on the control's hard disk before it is shipped
from the factory.
With the print masks, the output format of the measurement results is defined
in the %TCHPRNT.A file:
7
77
7 In the MOD menu RS232/RS422 Setup in the PRINT line, define the path
for the %TCHPRNT.A file:
If the path name begins with RS232:\ or RS422:\, the measurement results are
transferred over the data interface.
If no path is entered, the file is saved in the root directory TNC:\.
7
77
7 Start the output of the measurement data with the PRINT soft key in the
manual probe cycle.
If you do not wish to use the standard print masks, you can create you own
print masks:
7
77
7 Save these masks in the language-specific paths on the PLC partition
(See "Conversational Language on page 6 325).
File names of the
individual print
masks
n Calibration for length, triggering touch probe: TSLCAL.A
n Calibration for radius, triggering touch probe: TSRCAL.A
n Basic rotation: ROT_2PTS.A
n Point measuring: DAT_SURF.A
n Corner as datum: DAT_CORN.A
n Circle center as datum: DAT_CC.A
n Basic rotation over 2 holes: ROT_2HLS.A
n Datum over 4 holes: DAT_IS4H.A
n Circle center over 3 holes as datum: DAT_CC3H.A
n Calibration for length, measuring touch probe: TBLCAL.A
n Calibration of measuring touch probe: TMCAL.A
Format of the print
masks
For the text lines of the print masks:
n Lines of text must be put into quotation marks.
n Each line must be concluded with a semicolon.
n Format instructions can be given from the programming language C.
n Variables of the format instructions must be separated by commas and
placed after the text string.
n The special commands MM and INCH switch the display to mm or inches.
The commands affect only number types that allow an inch representation.