6 – 340 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9182 Re-enabling individual NC keys
With this module you cancel the effect of Module 9181.
Call:
PS B/W/D/K <Key code>
CM 9182
PL B/W/D <Error status>
0: NC key enabled
-1: For error see W1022
Error recognition:
Module 9183 Disabling groups of NC keys
The key-group codes are:
n 0: All keys
n 1: ASCII
n 2: Soft keys, Page Up/Down
n 3: Cursor, ENT, NOENT, DEL, END, GOTO
n 4: Numbers, algebraic signs, decimal point, actual position capture
n 5: Operating modes
n 6: Block opening keys
Call:
PS B/W/D/K <Key group code>
CM 9183
PL B/W/D <Error status>
0: Group of NC keys disabled
–1: Transferred value> maximum value
Error recognition:
Marker Value Meaning
M4203 0 Disabling was cancelled
1 Error code in W1022
W1022 1 Transferred parameter > maximum value
2 Transferred parameter invalid
Marker Value Meaning
M4203 0 The group of NC keys was disabled
1 Error code in W1022
W1022 2 Transferred parameter invalid