4 10 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9310 Read the machine parameter from the run-time memory
With this module you can read the value of the given machine parameter from
the run-time memory. The input value is transferred as a natural number with
the decimal point shifted by the number of possible decimal places.
A value is read from the run-time memory.
For non-indexed machine parameters, zero must be transferred as the index.
Call:
PS B/W/D/K <MP number>
PS B/W/D/K <MP index>
CM 9310
PL B/W/D <MP value / Error code>
1: MP number does not exist
6: Call was not in a submit or spawn job
7: MP is of the string type
8: No system memory
Error recognition:
Marker Value Meaning
M4203 0 MP was read
1 Error code in W1022
W1022 20 Module was not called in a spawn job or submit job