EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - Connecting the PL 4 Xxb Input;Output Unit

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
December 2001 Connecting the PL 4xxB Input/Output Unit 3 83
3.16 Connecting the PL 4xxB Input/Output Unit
Up to four PL 4xxB can be connected to the TNC.
TNC 426 CB, TNC 430 CA:
One PL can be mounted in the logic unit, additional PLs are mounted in the
electrical cabinet.
TNC 426 PB/M, TNC 430 PA/M:
The PLs must be mounted separately in the electrical cabinet.
The PL 410B is available with and without analog inputs.
No more than one PL 405B may be used. If connecting through PL 410B, the
PL 405B must be connected last.
Device Id. Nr. Switching
inputs
24 Vdc
Switching
outpt.
24 Vdc
Analog inputs
(±10 V)
Inputs for Pt 100
thermistors
PL 410B 263 371-xx 64 31 ––
PL 410B 263 371-xx 64 31 4 4
PL 405B 263 371-xx 32 15 ––

Table of Contents

Related product manuals