December 2001 Display and Operation 6 – 329
MP7237 Displaying and resetting the operating times
Format: %xxxxxxxx
MP7237.0 Displaying PLC operating times
Input: Bits 0 to 7 represent PLC operating times 1 to 8
0: Do not display
1: Display
MP7237.1 Resetting PLC operating times with the code number 857282
Input: Bits 0 to 7 represent PLC operating times 1 to 8
0: Do not reset
1: Reset
MP7237.2 Resetting NC operating times with the code number 857282
Input: Bit 0 – No function
Bit 1 – “Machine on” operating time
Bit 2 – “Program run” operating time
0: Do not reset
1: Reset
MP7238.0-7 Dialog messages for PLC operating times 1 to 8
Input: 0 to 4095
Dialog no. from the file PLCDIALOG= (OEM.SYS)
Module 9190 Starting the operating times
You start one or more operating times.
Call:
PS B/W/D/K <PLC operating time>
Bits 0 to 7 represent PLC operating times 1 to 8
CM 9190
Error recognition:
Module 9191 Stopping the operating times
You stop one or more operating times.
Call:
PS B/W/D/K <PLC operating time>
Bits 0 to 7 represent PLC operating times 1 to 8
CM 9191
Error recognition:
Marker Value Meaning
M4203 0 PLC operating time started
1 Incorrect parameter
Marker Value Meaning
M4203 0 PLC operating time started
1 Incorrect parameter