December 2001 List of Machine Parameters 4 – 13
4.3 List of Machine Parameters
4.3.1 Encoders and Machines
MP Function and input Software
version and
behavior
Page
MP10 Active axes
Format: %xxxxxxxxx
Input: Bits 0 to 8 correspond to axes 1 to 9
0: Axis not active
1: Axis active
RESET 6 – 5
MP20 Monitoring functions for the axes
Format: %xxxxxxxxx
Input: Bits 0 to 8 correspond to axes 1 to 9
0: Monitoring not active
1: Monitoring active
PLC
RUN
6 – 11
MP20.0 Absolute position of the distance-coded reference marks
MP20.1 Amplitude of encoder signals
MP20.2 Edge separation of encoder signals
MP21 Monitoring functions for the spindle
Format: %xx
Input: Bit 0 – Spindle 1
0: Monitoring not active
1: Monitoring active
Bit 1 – Spindle 2
0: Monitoring not active
1: Monitoring active
PLC
RUN
6 – 11
MP21.0 No function
MP21.1 Amplitude of encoder signals
MP21.2 Edge separation of encoder signals
MP100 Designation of axes
Format: XYZABCUVWxyzabcuvw-
Input: Characters 1 to 9 correspond to axes 1 to 9
PLC
RUN
6 – 5,
6 – 28
MP100.0 Traverse range 1
MP100.1 Traverse range 2
MP100.2 Traverse range 3
MP110.0-8 Assignment of position encoder inputs to the axes
Input: 0: No position encoder input
1 to 6: Position encoder inputs X1 to X6
35 to 38: Position encoder inputs X35 to X38
6 – 16