EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - Configuration of the Data Interface

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
December 2001 List of Machine Parameters 4 37
4.3.8 Configuration of the Data Interface
MP Function and input Software
version and
behavior
Page
MP5000 Disable data interfaces
Input: 0: No interface disabled
1: RS-232-C/V.24 interface disabled
2: RS-422/V.11 interface disabled
PLC
RUN
8 15
MP5020 Configuration of the data interface
Format: %xxxxxxxx
Input: Bit 0
0: 7 data bits
1: 8 data bits
Bit 1
0 = Any BCC character
1 = BCC not control character
Bit 2
0: Transmission stop by RTS not active
1: Active
Bit 3
0: Transmission stop by DC3 not active
1: Active
Bit 4
0: Character parity even
1: Odd
Bit 5
0: Character parity not desired
1: Desired
Bit 6 = 0, Bit 7 = 0: Length of the stop: 1.5 bits
Bit 6 = 1, Bit 7 = 0: Length of the stop: 2 bits
Bit 6 = 0, Bit 7 = 1: Length of the stop: 1 bits
Bit 6 = 1, Bit 7 = 1: Length of the stop: 1 bits
PLC, CN123
RUN
8 18
MP5020.0 Operating mode EXT1
MP5020.1 Operating mode EXT2
MP5020.2 Operating mode EXT3 (PLC)
MP5030 Data transfer protocol
Input: 0 = Standard data transfer protocol
1 = Blockwise transfer
2 = Without protocol (only for MP5030.2)
PLC, CN123
RUN
8 18
MP5030.0 Operating mode EXT1
MP5030.1 Operating mode EXT2
MP5030.2 Operating mode EXT3 (PLC)

Table of Contents