6 – 168 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9160 Status request for temperature monitoring and I
2
t
monitoring
Call:
CM 9160
PL D <Temperature monitoring>
Bit 31 15 876543210
Axis: Sxxxxx987654321
PL D <I2t monitoring>
Bit 31 16 15 876543210
Axis xxxxxxx987654321 Sxxxxx987654321
I
2
t limit I
2
t early warning
Error recognition:
6.11.9 Monitoring of Power Supply Unit and DC-Link Voltage (digital axes only)
At X51 to X59 and X61 the ready signal is available at pin 6.
The signal is reset for the following reasons:
n The connection of K9 to K663 on the HEIDENHAIN interface PCB is not
closed (with SIMODRIVE inverter system)
n Voltage from the unit bus (FR+) is missing (with SIMODRIVE inverter
system)
n Error in the power supply unit (+5 V or U
z
is missing or U
z
is too large)
As soon as the readiness signal is reset, the drive controllers are switched off.
Normally, the error message MOVEMENT MONITORING IN <AXIS> A is output
through the position control loop.
Subsequently, the PWM signal release is switched off by the reset signal.
After the drive controller is switched on with Module 9161, you can use
Module 9162 to interrogate the readiness of the drive controller ((See
“Module 9162 Status request of the drive controller” on page 6 – 145)).
Marker Value Meaning
M4203 0 No error
1 Control has no current controller